We want to ensure your employees, and ours are safe, and the risk of covid transmission is practically zero.These products will be for any range from small home products up to large data centre and heavy industry products.
Our number one priority is safety and even more so now during this pandemic. The result is a growing need for reliable, ultra-compact power-protection solutions. MGE UPS Systems meets this need with Pulsar Evolution, the ideal high-density power-protection solution for networking equipment, rack-optimized servers, traditional rack and tower servers and network storage systems. Pulsar Evolution uses a high-frequency Line-Interactive technology to bring users an ultra-compact UPS that delivers a sinewave output, correcting voltage variations and offering wide input voltage tolerances (up to 150V - 294V). UPS-Driver software, supplied with every UPS, lets you adjust the main operating parameters to ensure compatibility with all situations, in particular with respect to input voltage tolerances and UPS sensitivity. Mge Pulsar Evolution 2200 Software Informer Serial Port ForPulsar Evolution UPSs come with a USB port and a serial port for compatibility with the existing and future machines. And last but not least, Pulsar Evolution UPSs come with 2 or 4 programmable outlets that can be used to reset network devices remotely and allocate longer backup times to the most critical equipment. Disconnecting all sources of supply before battery replacement. Connection to any other type of receptacle other than a two-pole, three-wire grounding receptacle may result in s shock hazard as well as violate local electrical codes. In the event of an emergency, turn the power switch to the off position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. Mge Pulsar Evolution 2200 Software Informer Free Of ConductiveThis unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. ![]() Unplug the UPS prior to cleaning and do not use liquid or spray detergent. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: 1) Remove watches, rings, or other metal objects from the hand. Use tools with insulated handles. Wear rubber gloves and boots. Do not lay tools or metal parts on the top of batteries. Disconnect charging source prior to connecting or disconnecting batteries terminal. Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. When replacing batteries, replace with the same number of the sealed lead-acid batteries. Wichtige Sicherheitshinweise Bitte lesen Sie diese Hinweis sorgfaltig durch. ![]() Entsorgung gebrauchter Batterien nach Angaben des Herstellers. ![]() Fault LED 2. AC Mode: Load Level LEDs Backup Mode: Battery Capacity LEDs 3. Power ONOFF Switch Back Panel 6 Installation and Operation Installing the UPS is as easy as following the steps shown. Be aware of the Power Switch must be kept in the ON position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS unit away from monitor at least 20cm to avoid interference. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours. Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices). ModemPhoneline Connection Plug incoming internet line into the In socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS. Serial Cable Connection To allow for unattended system shutdown for your operating system, connect the serial cable as per diagram below. Turn OnOff To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again. DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. Battery Removal Follow the Chart 1 to Chart 3 to replace the batteries.
0 Comments
Leave a Reply. |